Transducers and Transmitters

Transducers and Transmitters - Pressure Transducers



SL17 - Submersible Pressure Transmitter
The Ashcroft® SL17 submersible transmitter combines ruggedness with proven sensor technology for satisfying challenging applications.


Accuracy

Output

Ranges

±0.25% for ranges > 1.5 psi, ±0.5% for 1.5 psi

4-20 mA

1.5 to 300 psi

T2 Pressure Transducer
The Ashcroft® T2 pressure transducer provides outstanding integrity concerning high shock, vibration and pressure cycling.


Accuracy

Output

Ranges

±0.25% of span

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

30 to 20,000 psig, compound to 300 psig


G2 Pressure Transducer
The Ashcroft® G2 combines performance with value. A versatile product platform, it excels in even the most challenging application.


Accuracy

Output

Ranges

±1% span: total error band through -20/85°C (-4/185°F), ±1.5% span: through -40/-20°C (-40/-4°F) and 85/125°C (185/257°F)

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

30 to 20,000 psig, compound to 300 psig

G3 Pressure Transducer
The Ashcroft G3 pressure transducer is a highly accurate, compact, economical and repeatable transducer for gauges and absolute pressure ranges.


Accuracy

Output

Ranges

±1.5% span: total error band through -20/85°C (-4/185°F), ±2% span: total error band through -40/-20°C (-40/-4°F) and 85/125°C (185/257°F)

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

vacuum, compound and 5 to 300 psig, 15 to 300 psia


A2 Industrial Pressure Transmitter
The Ashcroft® A2 industrial pressure transmitter is designed to satisfy the requirements of industrial applications.


Accuracy

Output

Ranges

±0.25, ±0.5, ±1% of span

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

15 to 7500 psi absolute, 1.5 to 10,000 psig, compound to 100 psig

A4 Intrinsically Safe/Non-Incendive Pressure Transmitter
The Ashcroft® A4 pressure transmitter fulfills a wide spectrum of pressure sensing requirements where Intrinsically Safe or Non-Incendive hazardous location ratings are needed.


Accuracy

Output

Ranges

±.25, ±0.5, ±1.0% of span

4-20mA

15 to 7500 psi absolute, 1.5 to 10,000 psig, compound to 100 psig


A2X Explosion/Flame Proof Pressure Transmitter
The Ashcroft® A2X pressure transmitter fulfills a wide spectrum of pressure sensing requirements when explosion and flame-proof hazardous location ratings are needed.


Accuracy

Output

Ranges

±0.25, ±0.5, ±1.0% of span

4-20mA, 0-5Vdc, 0-10Vdc, 1-5Vdc, 1-6Vdc, 0.5-4.5Vdc (ratiometric)

15 to 7500 psi absolute, 1.5 to 10,000 psig, compound to 100 psig

K1 Pressure Transducer/Transmitter
The Ashcroft® K1 is a proven and versatile pressure transducer/transmitter. Sensor technology and assembly method eliminates signal instability and drift; making this product virtually unaffected by shock or vibration.


Accuracy

Output

Ranges

±0.5%, ±1.0% of span

4-20mA, 1-5Vdc, 1-6Vdc, 1-11Vdc

15 to 20,000 psig, compound to 60 psig


K2 Pressure Transducer with Millivolt Output
The Ashcroft® K2 shares the same platform as the model K1, except offered with a millivolt option.


Accuracy

Output

Ranges

±0.5%, ±1.0% of span

2, 3, 10, 20 mV/V

15 to 20,000 psig, compound to 60 psig

KX Flush Mount Pressure Transducer
The Ashcroft® KX pressure transmitter combines benefits of polysilicon thin film performance with the utility of a flush-mounting sensing diaphragm.


Accuracy

Output

Ranges

±1.0% of span

4-20mA, 1-5Vdc, 1-6Vdc

100 to 5000 psig


KS Sanitary Transducer/Transmitter
The Ashcroft® KS sanitary pressure transducer/transmitter combines proven polysilicon thin film technology with diaphragm seal expertise.


Accuracy

Output

Ranges

±1.0% of span

4-20mA, 1-5Vdc, 1-6Vdc, 2, 3, 10, 20 mV/V ratiometric

30 to 1000 psig, compound to 100 psig

K8 Pressure Sensor
The Ashcroft® K8 is a proven reliable pressure sensor.


Accuracy

Output

Ranges

±0.5%, ±1.0% of span

Varies from 6-18mV/V at span ratiometric

45 to 20,000 psig


KM15 OEM Pressure Transducer
The Ashcroft® KM15 pressure transducer is ideal when a durable and economical pressure transducer is needed.


Accuracy

Output

Ranges

100 psig and above - ±0.5% of span , 75 psig and below - ±1.0% of span

1-5Vdc, 1-6Vdc, 0.5 - 4.5Vdc (ratiometric)

15 to 7500 psig, compound to 300 psig

GC31 Indicating Pressure Transducer with Switch Outputs
The Ashcroft® GC31 is an ultra compact indicating transducer with analog scaling and switch outputs.


Accuracy

Output

Ranges

±1.0% of span

1-5Vdc

Gauge: 50 to 1500 psig, Compound: -15 to 15 psig thru -15 to 300 psig


GC35 Indicating Pressure Transducer with Switch Outputs
The Ashcroft® GC35 is a compact indicating transducer with analog scaling and switch outputs.


Accuracy

Output

Ranges

±1.0% of span

4-20mA

Gauge: 50 to 7500 psig, Compound: -15 to 75 psig thru -15 o 300 psig

GC51 Rangeable Indicating Pressure Transmitter
The Ashcroft® GC51 pressure transmitter incorporates field-proven thin film technology, and can be used for monitoring a wide variety of wet or dry media.


Accuracy

Output

Ranges

±0.25% of span (URL)0

4-20mA (2 wire)

Gauge: 50 to 7500 psig, Compound: -15 to 15 psi thru -15 to 50 psi


GC55 Wet/Wet Indicating Differential Pressure Transducer with Switch Outputs
The Ashcroft® GC55 is a high-differential pressure transducer incorporating two thin film sensors; unit output signaling may be connected to external controls or data acquisition.


Accuracy

Output

Ranges

±0.5% of span

4-20mA, 1-5Vdc

Differential: 75 to 300 psid

GC30 Indicating Differential Pressure Transducer with Switch Outputs
The Ashcroft® GC30 differential pressure transducer uses field-proven thin film sensor technology for monitoring a wide variety of applications.


Accuracy

Output

Ranges

±1.5% of span

1-5Vdc

Gauge: 0.25 I.W.C. to 25 I.W.C., Compound ±0.25 I.W.C to ±25 I.W.C.


GC52 Rangeable Wet/Wet Differential Pressure Transmitter
The Ashcroft® GC52 wet/wet differential pressure transmitter where consistent, reliable low DP measurement is essential.


Accuracy

Output

Ranges

±0.50% of span (URL)

4-20mA (2 wire)

Bidirectional Inches of Water: ±4 to ±200 I.W.C., Unidirectional Inches of Water: 0 to 4 thru 400 I.W.C

 

CXLdp Differential Pressure Transmitter
The Ashcroft® CXLdp differential pressure transmitter uses the patented Si-Glas™ variable capacitance sensor, providing excellent sensitivity and long term stability.


Accuracy

Output

Ranges

±0.25%, ±0.4% or ±0.8% of span

4-20mA, 0-5Vdc, 0-10Vdc, (24Vac/Vdc)

Unidirectional: 0.10 to 0/25 I.W.C.: Bidirectional: ±0.10 to ±15 I.W.C.